Simulation analysis on temperature field and stress field in mass concrete of dock floor slab

吴丹 1田振华 2马文丽3

作者信息

  • 1. 河海大学水利水电工程学院,江苏南京210098
  • 2. 河海大学水文水资源与水利工程科学国家重点实验室,江苏南京210098
  • 3. 水资源高效利用与工程安全国家工程研究中心,江苏南京210098
  • 折叠

摘要

Abstract

Based on the heat-conduction equation and stress increment equation, the temperature field and stress field in the concrete of the floor slab of a dock placed with the interval of 7 d is calculated and analyzed through ABAQUS finite element analysis after 90 d of its placement. The result shows that the placement scheme of placing in four layers with the interval of 7 d can meet the concrete anti-cracking requirement concerned.

关键词

大体积混凝土/分层浇筑/温度场/应力场/船坞/港口工程

Key words

mass concrete/ layered placement/ temperature field/ stress field/ dock/ harbor engineering

分类

交通工程

引用本文复制引用

吴丹,田振华,马文丽..船坞底板大体积混凝土温度场及应力场仿真分析[J].水利水电技术,2011,42(1):41-43,3.

基金项目

国家自然科学基金资助项目(51079046,50909041,50809025,50879024) (51079046,50909041,50809025,50879024)