电感耦合等离子体发射光谱法测定锌精矿中的二氧化硅
Determination of SiO2 in Zinc Concentrates by Inductively Coupled Plasma-Atomic Emission Spectrometry
张宁 1刘海波 1方增坤1
作者信息
- 1. 厦门紫金矿冶技术有限公司,福建厦门,361101
- 折叠
摘要
Abstract
The zinc concentrates were digested by alkali fusion. The SiO2 in zinc concentrates were determined by inductively coupled plasma-atomic emission spectrometry (ICP-AES) with adding Au as internal calibration. The matrix interference effect was studied in this article. The matrix interference effect and the stability of instrument were worse along with Na increasing, which reduced accuracy of determination. The matrix interference effect and the instrument fluctuation have been overcome by using internal calibration. The determination limit of SiO2 was 0.0063 mg/L, and the determination content range was of 0. 02% - 10%. The results were in good agreement with the certified value of reference materials and the RSD (n =5) was less than 2%.关键词
锌精矿/二氧化硅/电感耦合等离子体发射光谱法Key words
zinc concentrates/ silicon dioxide/ inductively coupled plasma-atomic emission spectrometry引用本文复制引用