传感技术学报2009,Vol.22Issue(11):1576-1580,5.
脉冲漏磁检测技术中新型传感器设计及实验验证
Design and Validation of a New Sensor for Pulsed Magnetic Flux Leakage Testing
摘要
Abstract
The magnetic flux leakage(MFL) method is commonly used as an inspection technique for ferromagnetic structures. The principle of pulsed magnetic flux leakage testing(PMFL) is analyzed in this pa-paer. In order to overcome the shortages of traditional MFL measurement which is use the magnetic field density of x-axis component and z-axis component,technique of using three-dimensional (3D) pulsed magnetic leakage field is proposed and a kind of new sensor is designed to measure the 3D magnetic field component for defect detection and characterization. The finite element method(FEM) has been used to simulate and analyse the new kind of sensor. The experimental and FEM test results show that this new PMFL can potentially provide additional information about defects.关键词
电磁无损检测/脉冲漏磁检测/传感器/有限元法/三维场测量Key words
electromagnetic nondestructive testing/pulsed magnetic flux leakage testing/sensor/finite element method/3D magnetic field measurement分类
信息技术与安全科学引用本文复制引用
唐莺,罗飞路,胡祥超,李季..脉冲漏磁检测技术中新型传感器设计及实验验证[J].传感技术学报,2009,22(11):1576-1580,5.基金项目
"十一五"预先研究项目资助(51317030106) (51317030106)