国际医药卫生导报2009,Vol.15Issue(22):78-80,3.DOI:10.3760/cma.j.issn.1007-1245.2009.22.031
石墨炉原子吸收光谱法测定尿铅的不确定度分析
Analysis of the uncertainty in the determination of the lead in human urine by graphite furnace atomic absorption spectrographic method
刘灵辉 1谷素英 1曾细嫦 1卓盈1
作者信息
- 1. 518103,深圳市宝安区福永预防保健所检验科
- 折叠
摘要
Abstract
Objective Analysis of the uncertainty in the measurement of lead in human urine by graphite furnace atomic absorption spectrometer was intreduced in this article.The sources of uncertainty and their effects on the total uneertainty were also analyzed.Methods Construct the mathematical model for evaluation of uncertainty in measurement based on a comprehensive understanding of the whole procedure of the determination.Results The measurement result of lead in human urine was given as (334.5±12.0)μg/L.Conclusions The major factor in influence on the determination of lead in human urine was the working curve fitting introduction error.关键词
石墨炉原子吸收光谱法/不确定度/铅Key words
Graphite furnace atomic absorption spectrometry/ Uncertainty in measurement/ Lead分类
医药卫生引用本文复制引用