由于传统的化学水处理方式有化学成分残留和环境污染问题,因而迫切需要开发新型的水处理技术.本研究针对现有杀菌消毒方法的不足之处,利用低温等离子体进行杀菌处理的实验研究,对电压、水层厚度、气体种类及电极形式的影响进行考察.结果表明,低温等离子体用于杀菌不仅效果显著,而且使用方便、快捷、安全并无残留,因而适于饮用水或者生活污水的杀菌处理.

Owing to the problem of residuals of chemical composition and environmental pollution caused by traditional chemical water treatment, new water treatment technologies should be developed imminently. In present study, non-thermal plasma technology was introduced to investigate sterilization effect against E. Coli in water. Experiments had been performed with different electrical voltage, water depth, gases and electrode fins. The results showed that non-therm…查看全部>>