原子能科学技术2009,Vol.43Issue(10):946-950,5.
γ全吸收型探测装置中子束流监视器的Geant4模拟
Geant4 Simulation of Neutron Beam Monitor in Gamma-Ray Total Absorption Facility
苏明 1仲启平 2郑玉来 2张奇玮 2阮锡超 2周祖英 2孔祥忠2
作者信息
- 1. 兰州大学,核科学与技术学院,甘肃,兰州,730000
- 2. 中国原子能科学研究院,北京,102413
- 折叠
摘要
Abstract
The relative detection efficiency of a lithium glass detector used as a neutron beam monitor in gamma-ray total absorption facility was simulated by Geant4. The neutron detection efficiency of the lithium glass detector was obtained between 10 keV and 1 MeV. Some factors affecting the efficiency were analyzed. The effect of the time delay caused by the elastic scattering upon TOF (time-of-flight) measurement, and the n-γ discrimination in different thickness lithium glass were discussed. The work will be helpful to understand better the neutron time of flight spectrum and energy spectrum from Li-glass detector which is used as a monitor of keV neutron source.关键词
γ全吸收型探测装置/中子监视器/Geant4Key words
gamma-ray total absorption facility/ neutron monitor/ Geant4分类
能源科技引用本文复制引用
苏明,仲启平,郑玉来,张奇玮,阮锡超,周祖英,孔祥忠..γ全吸收型探测装置中子束流监视器的Geant4模拟[J].原子能科学技术,2009,43(10):946-950,5.