摘要
Abstract
Suction penetration and ultimate uplift capacity are the two key issues in the design and construction of suction caissons used as suction anchors in deep water or multi-caisson foundations for the offshore platforms/wind turbines.A programme of large-scale model tests on a suction caisson is carried out in a large soil tank in Zhejiang University to study the behaviors of the caisson foundations during suction penetration and pullout.The test results of suction penetration show that the suction under the lid just has a slight influence on installation resistance of the caissons in silt,and the suction required to penetrate the caisson without soil piping is well predicted based on the results of CPT tests.The pullout tests with different loading rates are also carried out,and the results indicate that loading rate has little effect on the performance of the caisson foundation if a critical loading rate is surpassed.Based on the test results,the ultimate pullout capacities of the caissons in silt for different loading conditions are presented.关键词
吸力式桶形基础/粉土/沉贯/抗拔/承载力Key words
suction caisson/silt/penetration/pullout/bearing capacity分类
建筑与水利引用本文复制引用
朱斌,孔德琼,童建国,孔令刚,陈仁朋..粉土中吸力式桶形基础沉贯及抗拔特性试验研究[J].岩土工程学报,2011,33(7):1045-1053,9.基金项目
国家自然科学基金项目 ()