Objective To investigate the value of end -tidal CO2 (pET(CO2)) monitoring in pediatric patients under general anesthesia without tracheal intubation. Methods Forty children who were going to receive general anesthesia without tracheal intubation, The change of waveform and value of PET(C02) and respiration rate(RR), pulse oxygen saturation(SpO2) were studied, then the statistical analysis of the results was performed. Results All the SpO2 of pediatric patients were keeped beyond 95%, increases of pET(CO2) during the anesthesia were significantly(P<0.01), and the higest value was 8.7 kPa(65 mmHg). Conclusion CO2 accumulation is a common complication due to respiratory depression and respiratory tract obstruction in pediatric general anesthesia.pFT(CO2), monitoring through nasal cannula can improve the safety of children during pediatric general anesthesia. It is suggested that the PET(CO2) should serve as one of routine monitoring during pediatric general anesthesia without tracheal intubation.[Chinese Medical Equipment Journal,2011,32(8) :64,66]