中国药业2011,Vol.20Issue(17):28-29,2.
注射用还原型谷胱甘肽钠细菌内毒素检查法研究
Study on Bacterial Endotoxin Test in Reduced Glutathione Sodium for lnjection
王宗春 1姜俊勇 1周延安 1宋金春1
作者信息
- 1. 武汉大学人民医院药学部,湖北武汉,430060
- 折叠
摘要
Abstract
Objective To establish a method for the detection of bacterial endotoxin in Reduced Glutathione Sodium for Injection.Methods Three batch of samples were used for the experiment of interference test and bacterial endotoxin test in accordance with appendix ⅪE,volume two, China Pharmacopoeia 2010 edition.Results By using tachypleus amebocyte lysates whose sensitivity was 0.5 EU/mL, the sample did not interfere the congregating reactivity of tachypleus amebocyte lysate with bacterial endotoxin when the concentration of reduced glutathione sodium was below 8.0 g/L.Conclusion The method of bacterial endotoxin test is feasible for the Reduced Glutathione Sodium for Injection.关键词
注射用还原型谷胱甘肤钠/细菌内毒素/鲎试剂Key words
Reduced Glutathione Sodium for Injection/bacterial endotoxin/tachypleus amebocyte lysate分类
医药卫生引用本文复制引用
王宗春,姜俊勇,周延安,宋金春..注射用还原型谷胱甘肽钠细菌内毒素检查法研究[J].中国药业,2011,20(17):28-29,2.