摘要

Abstract

The mathematic model of aquifer particles migration induced by groundwater source heat pump (GWSHP) pumping was theoretically presented. A case which represents the influence of constant pressure difference on aquifer permeability induced by GWSHP pumping was analysed. The results indicate that the hydraulic conductivity increases by 156,16 and 7 times respectively as aquifer porosity increases 2.57,1.86 and 1.59 times respectively of initial value 20,25 and 30 m in five-year operation of GWSHP for different aquifer thicknesses. Considering particles migration, the permeability of aquifer is affected obviously by GWSHP pumping under constant pressure difference.

关键词

地下水源热泵/定压差/含水层/渗透性

Key words

groundwater source heat pump/ constant pressure difference/ aquifer/ permeability