浙江大学学报(理学版)2011,Vol.38Issue(4):433-435,488,4.DOI:10.3785/j.issn.1008-9497.2011.04.015
离子交换电雾检测测定CO2吸收液中一乙醇胺、二乙醇胺、N-甲基二乙醇胺
Determination of monoethanolamine, diethanolamine and diethanolmethylamine in the absorption liquid of CO2 by ion chromatography with charged aerosol detector
摘要
Abstract
A method was developed for the determination of monoethanolamine, diethanolamine and Diethanolmeth-ylamine in the absorption liquid of CO2 by cation-exchange ion chromatography with charged aerosol detector (CAD). Chromatographic separation was performed on a Dionex IonPac CS17(250×4 mm) , fomic acid and acetoni-trile were used as eluent, respectively. The effects of the types of column, eluent, eluent concentration of organic alcohol amines were investigated. The linear ranges of the method for three alcohol amines were 1. 0~100μg · mL-1 , the correlation coefficients were 0. 9996, 0. 9993 and 0. 9992, and the detection limits ( S/N = 3) were 0. 21,0. 04, 0. 32 μg · mL-1 respectively. The method was successfully applied to determine organic alcohol amines in real sample. The recoveries of three organic alcohol amines after spiking were from 87% to 98%.关键词
阳离子交换/电雾检测器/有机醇胺Key words
cation-exchange/charged aerosol detector/organic alcohol amine分类
化学化工引用本文复制引用
叶明立,陈郁..离子交换电雾检测测定CO2吸收液中一乙醇胺、二乙醇胺、N-甲基二乙醇胺[J].浙江大学学报(理学版),2011,38(4):433-435,488,4.基金项目
浙江省自然科学基金资助项目(Y2110945,R4080124,Y507252) (Y2110945,R4080124,Y507252)
浙江省分析测试基金资助项目(2007F70061). (2007F70061)