| 注册
首页|期刊导航|生物加工过程|适配子纳米生物传感器在青霉素检测中的应用

适配子纳米生物传感器在青霉素检测中的应用

孙坤 张娟琨 徐培东 王明伟 林青 徐锦锋 宋可

生物加工过程2011,Vol.9Issue(4):58-63,6.
生物加工过程2011,Vol.9Issue(4):58-63,6.DOI:10.3969/j.issn.1672-3678.2011.04.013

适配子纳米生物传感器在青霉素检测中的应用

Application of aptamer nano-biosensor in penicillin detection

孙坤 1张娟琨 1徐培东 1王明伟 1林青 1徐锦锋 1宋可1

作者信息

  • 1. 天津科技大学生物工程学院天津市工业微生物重点实验室教育部工业微生物重点实验室,天津,300457
  • 折叠

摘要

Abstract

Porous silicon (PS) was made from silicons by a pulsed current etching method. Three methods were tested to choose the best way of immobilizing penicillin aptamer on glass sheet, called the cova-lent bonding method, ion-absorbing method, and APTES-modified glutaraldehyde cross-linking method. After penicillin aptamer was immobilized on the modified PS, the impedances were determined and compared by AC impedence method under conditions of adding and without adding penicillin. Then, an equivalent circuit was established for impedance fitting. The Nyquist plots of PS sensor could prove that the aptamer was immobilized and the nano-biosensor established. The linear range of the sensor was 0. 05 -0. 20 mg/L. The sensitivity limit was 0. 05 mg/L.

关键词

适配子/生物传感器/多孔硅

Key words

aptamer/ biosensor/ porous silicon

分类

医药卫生

引用本文复制引用

孙坤,张娟琨,徐培东,王明伟,林青,徐锦锋,宋可..适配子纳米生物传感器在青霉素检测中的应用[J].生物加工过程,2011,9(4):58-63,6.

基金项目

科技部资助项目(2009CJA10047) (2009CJA10047)

天津市科委资助项目(07ZHXHNC04500,09ZCZDSF04200) (07ZHXHNC04500,09ZCZDSF04200)

生物加工过程

OACSCDCSTPCD

1672-3678

访问量2
|
下载量0
段落导航相关论文