| 注册
首页|期刊导航|水力发电|基于故障树分析的闸门双吊点液压启闭系统故障诊断研究

基于故障树分析的闸门双吊点液压启闭系统故障诊断研究

赵新泽 杨明松 彭巍 张勤超

水力发电2011,Vol.37Issue(8):68-70,100,4.
水力发电2011,Vol.37Issue(8):68-70,100,4.

基于故障树分析的闸门双吊点液压启闭系统故障诊断研究

Fault Diagnosis of the Twin-lift Hydraulic Hoist System Based on Fault Tree Analysis

赵新泽 1杨明松 1彭巍 1张勤超2

作者信息

  • 1. 三峡大学机械与材料学院,湖北宜昌443002
  • 2. 特变电工衡阳变压器有限公司,湖南衡阳421007
  • 折叠

摘要

Abstract

Based on the Fault Tree Analysis (FTA), the fault tree of twin-lift hydraulic hoist system for gate is established by analyzing system failure form, system structure and the logical relationship between the parts and the system and taking the faults as the top event. The qualitative and quantitative analyses are carried out through computing the minimum cut sets and the importance. The results show that the fault is mainly caused by the wear of hydraulic components and the jamming of valve spool. The study can provide guidance to routine maintenance and repair.

关键词

液压启闭系统/故障树/最小割集

Key words

hydraulic hoist system/ fault tree/ minimum cut sets