特高压直流换流阀单阀交流试验方法研究

Study on AC Voltage Test Method of UHVDC Valve

李强 1周敏刚 1陈楠 1杨涛 1党原 1贾涛 1张小勇1

作者信息

  • 1. 西安高压电器研究院有限责任公司,西安710077
  • 折叠

摘要

Abstract

± 800 kV DC transmission is a current transmission approach of the world' s highest level in the area of the direct current transmission system. ±800 kV HVDC thyristor valve is the key equipment in Ultra-High Voltage DC (UHVDC) transmission. It must be taken rigorously type test before put into operation. AC voltage test of single valve is a special test item in the valve dielectric tests. In this paper, taking the first domestic independent testing, ± 800 kV thyristor valve dielectric test, as an example, introduces the associated electrical structure, and studies the test methods on single valve' s AC voltage test.

关键词

换流阀/交流耐压/单阀/绝缘型式试验

Key words

thyristor valve/ AC voltage withstand test/ single valve/ dielectric type test