准分子激光术后3种屈光测量法的研究

顾刘伟 袁志兰 周行涛

南京医科大学学报(自然科学版)2011,Vol.31Issue(6):889-893,5.
南京医科大学学报(自然科学版)2011,Vol.31Issue(6):889-893,5.

准分子激光术后3种屈光测量法的研究

Analysis of three different refraction measurement after excimer laser corneal refractive surgery

顾刘伟 1袁志兰 1周行涛2

作者信息

  • 1. 南京医科大学第一附属医院眼科,江苏南京,210029
  • 2. 复旦大学附属眼耳鼻喉科医院,上海,200031
  • 折叠

摘要

Abstract

Objective:To investigate the refraction accuracy of three different measurements and their influencing factors after ex-cimer laser comeal refractive surgery. Methods: Seventy-eight cases (154 eyes) performed with Excimer laser corneal refractive surgery from optometry clinic, the Eye Ear Nose and Throat Hospital, FuDan University were selected randomly from Dec 2008 to Jan 2009. Sphere,cylinder and cylinder axial of all the patients were measured three months (mean 14.2 weeks)before and after surgery by auto-refractomer wavefront analyzer and phoropter inspection (without cycloplegic). Higher-order aberration, corneal curvature and corneal thickness of every patient were also measured at the same time before and after surgery. Results: The cylinder of auto-refractor and phoropter were significantly different respectively (P<0.05). Sphere, cylinder and cylinder axial of auto-refratomer and phoropter were significantly different (all P<0.01) respectively. Sphere of wavefront analyzer and phoropter were statistician different (P < 0.01).The differences of sphere between auto-refratomer and phoropter were found to be related to the corneal curvature, (the regression coefficient is -0.07, P=0.009, P < 0.01). The differences of sphere between waverfront analyzer and phoropter were found to be respectively related to high order wave aberration (C7, C12 )and corneal curvature (The regression coefficient is -0.475, 0.489,-0.004,respectively, and P was 0.001, 0.001, 0.024, respectively). Conclusion: The accuracy of low order wave aberration is better than that of auto-refractomer in measuring refraction especially after surgery. The differences of which the accuracy of preoperative and postoperative measurement of the same eye with three instruments mainly relates to the changes of curvature of the comea and higher-order aberrations after the excimer laser corneal refractive surgery.

关键词

像差仪/电脑验光仪/屈光手术/验光

Key words

wavefront analyzer/autorefraction/refractive surgery/optometry

分类

医药卫生

引用本文复制引用

顾刘伟,袁志兰,周行涛..准分子激光术后3种屈光测量法的研究[J].南京医科大学学报(自然科学版),2011,31(6):889-893,5.

南京医科大学学报(自然科学版)

OA北大核心CSCDCSTPCD

1007-4368

访问量0
|
下载量0
段落导航相关论文