医疗卫生装备2011,Vol.32Issue(9):22-23,42,3.
高效液相色谱仪标准物质丙三醇水溶液的研制
Development of Reference Material for Refractive Index Detector of HPLC
摘要
Abstract
Objective To develop the reference material of glycerol/water for refractive index delecior(RID) of HPLC according to verification regulation. Methods Three kinds of reference material were made up by weighing method. The homogeneity and stability were detected by RID, and the uncertainties were also analyzed. Remits The homogeneity and stability of the reference material were good within 6 months; The uncertainties of the reference material of 1.00×10-1 g/mL, 1.00×l0-3 g/mL, 1.00×10-5 g/mL were 0.89%, 0.90% and 1.1% respectively, their extend uncertainties were 2%(k=2), 2%(k= 2) and 3% (k =2) respectively. Conclusion The reference material can be used for verifying RID.关键词
液相分析仪/示差折光检测器/标准物质/均匀性/稳定性/不确定度Key words
HPLC/RID/reference material/homogeneity/stability/uncertainty分类
机械制造引用本文复制引用
沈娟,吴建刚,李咏雪,赵鹏,马飞..高效液相色谱仪标准物质丙三醇水溶液的研制[J].医疗卫生装备,2011,32(9):22-23,42,3.基金项目
总后卫生部药品仪器检验所苗圃基金资助(2008q005) (2008q005)