建筑结构学报2011,Vol.32Issue(7):127-132,6.
混凝土框架顶部钢结构加层连接节点抗震性能试验研究
Experimental study on seismic behavior of joints between concrete frame and added top steel stories
宗钟凌 1曹双寅 2张皓 2潘宇翔 3吕凤伟2
作者信息
- 1. 淮海工学院土木工程学院,江苏连云港,222005
- 2. 东南大学土木工程学院,江苏南京,210096
- 3. 中国联合工程公司,浙江杭州,310022
- 折叠
摘要
Abstract
The seismic behavior of three types of joints ( bolted joint, welded joint and expanded section joint ) between a concrete frame and the added top steel stories was investigated under low cycle load reversals. Performance of the test specimens was evaluated in terms of failure mode, joint shear deformation, energy dissipation capacity and ductility, etc. The test results reveal that all joints fail due to concrete crushing and rupture of longitudinal bars as a result of plastic hinges formed at the fixed beam end. The performance of bolted and welded joints are favorable. The transfer steel plate has no visible deformation. The energy dissipation capacity of the increased section joint is better than that of the bolted and welded joints. The construction technique of bolted and welede joint are simple. The results in this paper are useful to the design and construction of steel adding stories on top of the concrete frame.关键词
钢结构加层/框架节点/拟静力试验/抗震性能Key words
added steel storey/ frame joint/ pseudo-static test/ seismic behavior分类
建筑与水利引用本文复制引用
宗钟凌,曹双寅,张皓,潘宇翔,吕凤伟..混凝土框架顶部钢结构加层连接节点抗震性能试验研究[J].建筑结构学报,2011,32(7):127-132,6.