D/UL can be used as flocculation indicator in theory when it is related to flow status and floccu-lation effect according to the dispersion model of reactor. Comparing with other flocculation indicator, the lab and pilot test results show that ;D/UL which reflects flocculation pool's performance can be used as flocculation indicator. The feasible D/UL value is 0. 06 ~ 0. 08, the best is about 0. 07. The value for mixing stage is 0. 20 ~ 0. 30. D/UL could be viewed as a new indicator for design and operation of flocculation pool because of its accuracy and easy operation.

关键词

分散模型/D/UL/絮凝控制指标/中试/停留时间分布

Key words

dispersion model/ D/UL / flocculation indicator/ pilot test/ RTD