首页|期刊导航|中国医学装备|不同抗凝剂对血糖检测结果的影响

不同抗凝剂对血糖检测结果的影响

洪燕英 郭海 韩晓禹 王岩 刘蔚 巫熙南 刘密凤

中国医学装备2011,Vol.8Issue(7):29-33,5.
中国医学装备2011,Vol.8Issue(7):29-33,5.

不同抗凝剂对血糖检测结果的影响

Effects of different anticoagulants on detecting results of blood glucose

洪燕英 1郭海 1韩晓禹 1王岩 1刘蔚 1巫熙南 1刘密凤1

作者信息

  • 1. 首都医科大学附属北京中医医院检验科,北京,100010
  • 折叠

摘要

Abstract

Objective: To evaluate the consistency of testing results of blood glucose (Glu) in heparin and EDTA anticoagulated blood specimens between 6 point-of-care testing (POCT) blood glucose meters and the VITROS 250 biochemical analyzer. Methods: The two kinds of anticoagulated blood samples were detected by 6 POCT blood glucose meters and the VITROS 250 biochemical analyzer, respectively. The detection results of POCT blood glucose meters in the two kinds of anticoagulated blood specimens were compared with those by VITROS 250 biochemical analyzer, which act as target value, then to calculate the relative bias. According to general specification in vitro diagnosetic lest systems for blood glucose self-test monitoring system (GB/T19654-2005). when the Glu>4.2 mmol/L or Glu<4.2 mmol/L, the results of relative deviation and absolute deviation were satisfactory and lower than 20% ,0.83 mmol/L, respectively. The detected results of heparin anticoagulated blood samples for each POCT glucose meter were analyzed to determine their correlation with EDTA anticoagulated blood. Results: When the values of glucose were over 4.2 mmol/L, the minimal and maximal deviation of the testing results from the POCT glucosemeters and the VITROS 250 biochemical analyzer was 0.5%, 28.6%, respectively, in heparin anlicoagulaled blood samples. It was 0.2%, 26.8%, respectively, in EDTA anticoagulated blood samples. When the values of glucose were less than 4.2mmol/l.. absolute deviation of the testing results from the POCT glucosemeters and the VITROS 250 biochemical analyzer was less than 0.83mmol/L in two anticoagulated blood samples. The detected results of heparin and EDTA anticoagulated blood had a good correlation and the correlation coefficient was over 0.95 (P<0.01). Conclusion: The testing results of the POCT glucosemeters are not different significantly in heparin and EDTA anlicoagulated blood samples as compared with the VITROS 250 biochemical analyzer.

关键词

床旁检验/血糖/抗凝剂/肝素/EDTA

Key words

POCT/ glucose/ decoagulant/ heparin/ EDTA

分类

临床医学

引用本文复制引用

洪燕英,郭海,韩晓禹,王岩,刘蔚,巫熙南,刘密凤..不同抗凝剂对血糖检测结果的影响[J].中国医学装备,2011,8(7):29-33,5.

中国医学装备

OACSTPCD

1672-8270

访问量0
|
下载量0
段落导航相关论文