医疗卫生装备2011,Vol.32Issue(10):119-120,2.
血液透析机质量控制数据分析
Data Analysis of Dialyzer Based on Quality Control
何树成 1李朝波 1王春梅 1张立海 1郭沁生 1梁宁1
作者信息
- 1. 066105河北秦皇岛 北京军区北戴河疗养院
- 折叠
摘要
Abstract
Objective To acquire the parameters of quality control testing so as to provide the basis for the dialyzer procurement, maintenance, and normal operation. Methods The study tested the machine cyclic which used the quality detector, and collected the first-hand information, for comparing on these three kinds of machines form many different parameters, such as dialysate conductivity, temperature and flow and so on, which was according to the instructions and the corresponding of higher order documents. Results The parameters of all three brands dialyzer met the technical requirements, but the error rate presented the different laws. Conclusion By analyzing the data, the error rate of GAMBRO'S dialyzer is smaller, and the performance is advantages based on its accuracy and stability. Metrological verification and quality control testing are important to the quality management of medical equipment. [Chinese Medical Equipment Journal,2011,32(10): 119-120]关键词
血液透析机/电导率/温度/流量/质量控制Key words
dialyzer, conductivity/ temperature/ flow/ quality control分类
机械制造引用本文复制引用