哈尔滨商业大学学报(自然科学版)2011,Vol.27Issue(4):561-565,5.
基于模糊控制的自来水厂除砷控制系统设计
Arsenic removal control system design of water factory based on fuzzy control
摘要
Abstract
In the process of water treatment, the arsenic content is an important control parameter, which directly affects the water quality and the health of the people. Arsenic removal is an important part of the water production process, it has a time - varying, delay, nonlinear characteristics. This paper used fuzzy control and conventional PID control combined control strategy, in the process of control, modifies, adjusted and improved the control rules online to achieve precise control and stability purposes. The results of experiments showed that this method had quick response speed, no overshoot and good robustness compared with the traditional controller.关键词
除砷/模糊PID控制/自整定/模糊控制器/偏差Key words
arsenic removal/ fuzzy PID control/ self-tuning/ fuzzy controller {deviation分类
资源环境引用本文复制引用
李晓军,王黎,高金良,陈晨,赵志领..基于模糊控制的自来水厂除砷控制系统设计[J].哈尔滨商业大学学报(自然科学版),2011,27(4):561-565,5.基金项目