流体机械2011,Vol.39Issue(7):60-64,5.DOI:10.3969/j.issn.1005-0329.2011.07.013
空调器离心风机内流场的PIV试验与CFD仿真对比分析
Analysis by PIV Measurement and CFD Simulation of Internal Flow Field of Centrifugal Fan of Air Conditioner
刘利娜 1邹建煌 1马重夫 1欧阳华2
作者信息
- 1. 珠海格力电器股份有限公司,广东珠海519070
- 2. 上海交通大学,上海200030
- 折叠
摘要
Abstract
Flow field at blades exit along with the height of centrifugal fan in indoor units of floor standing air conditioner was researched by Particle Imaging Velocimetry (PIV) measurement and Computational Fluid Dynamics (CFD) simulation. Based on the PIV measurements results, the CFD simulation model was proved to be available. From the CFD simulation result, the flow field at the clearance between the centrifugal fan inlet and guide shroud was obtained. According to the requirement of manufacture and assembly, an optimized design centrifugal fan improves the backflow and weakens turbulence noise at the clearance between the centrifugal fan inlet and guide shroud,and improves the use efficiency of centrifugal fan inlet part. By contrast with the original centrifugal fan, the performance characteristics experiment results show, the optimized one slightly improves the air flow rate, reduces the sound pressure level 1 dB/A, cuts down 2 ~ 5W fan motor power, and lightens the fan' s weight 350g (26.5%).关键词
柜式空调器室内机/离心风机/PIV/CFD/优化设计Key words
indoor units of floor standing air conditioner/centrifugal fan/PIV/CFD/optimized design分类
通用工业技术引用本文复制引用
刘利娜,邹建煌,马重夫,欧阳华..空调器离心风机内流场的PIV试验与CFD仿真对比分析[J].流体机械,2011,39(7):60-64,5.