西安工程大学学报2011,Vol.25Issue(3):352-356,5.
A/O2+酸析-催化氧化工艺处理精制棉废水的中试研究
The pilot test on the treatment of refined cotton wastewater by A/O2 + adification-catalytic oxidation process
同帜 1邹坦胜 2陈超产2
作者信息
- 1. 西安工程大学环境与化学工程学院,陕西西安710048
- 2. 西安青山环保科技有限责任公司,陕西西安710075
- 折叠
摘要
Abstract
A/O2 + adification-catalytic oxidation process is adopted to deal with the refined cotton wastewater which is one of the most intractable industrial wastewater, and there is a good result in the pilot test. In biological part, the removal rate of COD and color is respectively over 82% and 50%. When the pH in edification is about 2. 5, and the reagent dose of H2O2 and FeSO4 is respectively 0.8 mg/L and 160 mg/L, the main index COD of water after treatment drops below 135mg/L, and the color degree is less than 150 times. In addition, according to the observation, the dehydroenase's activity is higher, and the rotifer and vorticella are the dominant microbes in biological phase.关键词
A/O2工艺/酸析/催化氧化/中试研究/精制棉废水Key words
A/O2 process/adification/catalytic oxidation/pilot test/refined cotton wastewater分类
资源环境引用本文复制引用
同帜,邹坦胜,陈超产..A/O2+酸析-催化氧化工艺处理精制棉废水的中试研究[J].西安工程大学学报,2011,25(3):352-356,5.