化工环保2011,Vol.31Issue(5):444-446,3.
炼油废水中氨氮的去除与控制
Removal and Control of Ammonia Nitrogen in Refinery Wastewater
赵新1
作者信息
- 1. 中国石化上海高桥分公司,上海200137
- 折叠
摘要
Abstract
Based on the refinery wastewater quality and the existing equipments, the treatment process was improved with focus on the control of bio-nitration conditions. The ammonia nitrogen mass concentration of the effluent is decreased and the effluent quality can meet the discharge standards. The Iiomogenizer is used as pretreatment equipment before the aeration basin, the influent COD of the aeration basin can be decreased from 420 mg/L to 322 mg/L with 23. 3% of average COD removal rate. Adding NaOH solution into the influents of the Iiomogenizer and the contact oxidation pond can keep the system pH alkalescent, the ammonia nitrogen mass concentration of the effluent can be kept below 5.0 mg/L and the average ammonia nitrogen removal rate can be increased from 23.5% to 87.5%.关键词
炼油废水/硝化/氨氮/废水处理Key words
refinery wastewater/ nitration/ ammonia nitrogen/ wastewater treatment分类
资源环境引用本文复制引用
赵新..炼油废水中氨氮的去除与控制[J].化工环保,2011,31(5):444-446,3.