化工环保2011,Vol.31Issue(3):197-201,5.
双极膜电渗析法回收丙烯酸丁酯废水中的有机酸
Recovery of Organic Acid from Butyl Acrylate Wastewater by Bipolar Membrane Electrodialysis Process
摘要
Abstract
Sodium acrylate and sodium p-toluenesulfonate in butyl acrylate wastewater were transformed into acrylic acid and p-toluene sulfonic acid in a three-chambered bipolar membrane electrodialysis device, and then the organic acid solution was recovered. The effect of the volume ratio of initial solution in salt chamber to that in acid chamber on the transformation was studied. The experimental results show that: When the volume ratio is 5, the mass concentrations of acrylic acid and p-toluene sulfonic acid in the recovered solution are 161. 5 g/L and 25.0 g/L, respectively; During the electrodialysis process, the average current density is 18. 7 mA/cm2 with 77. 7% of current efficiency; The transformation rates of sodium acrylate and sodium p-toluenesulfonate are 98. 5% and 99.3% , respectively; The specific energy consumption is 0.172 kW ? H/mol.关键词
双极膜/电渗析/丙烯酸/对甲基苯磺酸/丙烯酸丁酯/废水/综合利用Key words
bipolar membrane/ electrodialysis/ acrylic acid/ p-toluene sulfonic acid/ butyl acrylate/ wastewater/ comprehensive utilization分类
化学化工引用本文复制引用
李鑫,宋玉栋,周岳溪,李福勤,康莹莹,许吉现..双极膜电渗析法回收丙烯酸丁酯废水中的有机酸[J].化工环保,2011,31(3):197-201,5.基金项目
国家水体污染控制与治理科技重大专项(2008ZX07207-004). (2008ZX07207-004)