Component analysis of EHV transmission line fault transient signals based on distributed parameter shows that the amplitude and the frequency of high frequency transient current signals after fault can reliably distinguish various fault types. So a faulty phase selection scheme based on high frequency transient current signals after fault is proposed. In this scheme, backward Porny algorithm and QR decomposition are employed, which makes the extraction of HF component more accurate and fast. A large number of ATP simulation results show that the proposed scheme can distinguish different fault types fast and correctly and it is not affected by transition resistances, inception angles, and load current.关键词
输电线路/故障选相/Prony/暂态量保护Key words
transmission line/ faulty phase selection/ Prony/ transient-based protection分类