摘要
Abstract
For the limitation of the dynamic and time-varying characteristics of the load simulator,a novel design method for the first-order electrical load is presented.By adjusting the turn-on time of switches,the first-order load with the parameters in a certain range can be simulated.The simulation degree of the electrical load might be judged with the area percent of function distance in the load response.For the simulations on three loads with cut-off frequencies as 20,50,80 Hz,the PWM period is 1 ms.The duty cycles are 9.9%,39.4% and 69.1%.The simulation deviations are 1.48%,3.92% and 3.57%.The results show that the first-order electrical load designed with this method can simulate any first-order load with the parameters in a certain range.关键词
一阶负载/脉宽调制/函数距离/模拟程度Key words
first-order load/PWM/function distance/simulation degree分类
信息技术与安全科学引用本文复制引用
程森林,叶兆虹,郭世刚,薛方正..一阶脉宽调制型负载[J].重庆大学学报:自然科学版,2011,34(12):82-87,6.基金项目
国家自然科学基金资助项目 ()