摘要
Abstract
Site error survey of voltage transformer is important content of electric energy metering device administration, relating to trading data between power plant and power corporation. Based on analysis of different data in a site error survey of voltage transformer, the effect of the secondary connection mode on the error survey data is discussed, and the mode of secondary connection to effect error survey data lowest is found.关键词
电能计量/电压互感器/误差测试/二次接线Key words
electric energy metering/ voltage transformer/ error determine/ secondary connection分类