| 注册
首页|期刊导航|电测与仪表|电压互感器现场误差测试二次接线方式解析

电压互感器现场误差测试二次接线方式解析

孙冲 王凯 耿建坡 王永辉 郑光明

电测与仪表2011,Vol.48Issue(11):37-40,4.
电测与仪表2011,Vol.48Issue(11):37-40,4.

电压互感器现场误差测试二次接线方式解析

The Research of Secondary Connection Method on Site Error Survey of Voltage Transformer

孙冲 1王凯 2耿建坡 1王永辉 1郑光明1

作者信息

  • 1. 河北省电力研究院,石家庄050021
  • 2. 伊春电业局营销部,黑龙江伊春153000
  • 折叠

摘要

Abstract

Site error survey of voltage transformer is important content of electric energy metering device administration, relating to trading data between power plant and power corporation. Based on analysis of different data in a site error survey of voltage transformer, the effect of the secondary connection mode on the error survey data is discussed, and the mode of secondary connection to effect error survey data lowest is found.

关键词

电能计量/电压互感器/误差测试/二次接线

Key words

electric energy metering/ voltage transformer/ error determine/ secondary connection

分类

信息技术与安全科学

引用本文复制引用

孙冲,王凯,耿建坡,王永辉,郑光明..电压互感器现场误差测试二次接线方式解析[J].电测与仪表,2011,48(11):37-40,4.

电测与仪表

OA北大核心CSTPCD

1001-1390

访问量1
|