电工技术学报2011,Vol.26Issue(11):150-154,167,6.
地面自动过分相中开关切换的瞬态过程研究
Research on Transient Process of Ground's Auto-Passing Neutral Section at Switching Time
冉旺 1李雄 1刘冰 1郑琼林1
作者信息
- 1. 北京交通大学电气工程学院,北京100044
- 折叠
摘要
Abstract
Based on the over-voltage waveforms measured in phase-separating section when the locomotives passing,the equivalent electrical parameters and mathematical model of contact net are researched.This paper proposes switch-ground's auto-passing neutral section to use power electronic switch.It could eliminate the over-voltage in the neutral section,meanwhile locomotives could pass the neutral section with load(not open the main circuit break).It is analyzed theoretically that overvoltage occurres when switches cut-off and cut-in.The simulation results show that the theoretical analysis is effective.关键词
地面自动过分相/截流过电压/合闸过电压/电力电子开关Key words
Ground's auto-passing neutral section/cut-off over-voltage/cut-in over-voltage/power electronics switch分类
信息技术与安全科学引用本文复制引用
冉旺,李雄,刘冰,郑琼林..地面自动过分相中开关切换的瞬态过程研究[J].电工技术学报,2011,26(11):150-154,167,6.