It analyzes the malfunction causes of CMI(Cascaded Multilevel Inverter) and gives the correct operation steps of cutting broken-down power unit.Consequence of cutting broken-down power unit directly is shown by simulation.On this basis,the concept and basic principle of cutting CMI malfunction power unit seamlessly are given and detailed theoretical analysis is carried on.At last,the specific control method of cutting CMI malfunction power unit seamlessly is also given.Simulation results show that the control strategy achieves the target of cutting CMI malfunction power unit seamlessly.

关键词

级联多电平逆变器/故障无缝切除/高压大功率/静止无功发生器

Key words

CMI(Cascaded Multilevel Inverter)/cutting malfunction power unit seamlessly/high voltage and high power/static reactive power generator