电力系统自动化2012,Vol.36Issue(4):45-49,5.
三相光伏并网逆变器电流扰动孤岛检测建模及分析
Modeling and Analysis of Current-disturbance Based Islanding Detection for Three-phase Photovoltaic Grid-connected Inverters
摘要
Abstract
Current disturbance is one of the methods for islanding detection.This paper presents the time-domain mathematic model for the three-phase photovoltaic grid-connected inverter.Based on this model the effects of the active and reactive current disturbances on the voltage frequency and amplitude at the point of common coupling are discussed.Quantitative analysis is also given.The islanding detection for three-phase inverter is simulated in the MATLAB/Simulink environment following IEEE Std.929—2000.The simulation results verify the theoretical analysis.The methods given in the paper are useful for minimizing the negative effect of the current disturbance on the power quality with the reliable islanding detection.关键词
孤岛检测/光伏发电/并网逆变器/电流扰动Key words
islanding detection/photovoltaic/grid-connected inverter/current disturbance分类
信息技术与安全科学引用本文复制引用
杨秋霞,赵清林,郭小强..三相光伏并网逆变器电流扰动孤岛检测建模及分析[J].电力系统自动化,2012,36(4):45-49,5.基金项目
国家自然科学基金重点项目 ()
河北省高等学校科学研究项目 ()
秦皇岛市科学技术研究与发展计划项目 ()