| 注册
首页|期刊导航|分析化学|流动相的pH值和离子强度对牛血清蛋白高效液相色谱手性柱分离性能的影响

流动相的pH值和离子强度对牛血清蛋白高效液相色谱手性柱分离性能的影响

熊雅进 苏文翠 章伟光 范军 郑盛润 林纯

分析化学2012,Vol.40Issue(1):89-94,6.
分析化学2012,Vol.40Issue(1):89-94,6.DOI:10.3724/SP.J.1096.2012.10181

流动相的pH值和离子强度对牛血清蛋白高效液相色谱手性柱分离性能的影响

Effect of Ionic-Strength and pH Value in Mobile Phase on EnantioSeparation of BSA High Performance Liquid Chromatography Column

熊雅进 1苏文翠 1章伟光 1范军 1郑盛润 1林纯1

作者信息

  • 1. 华南师范大学化学与环境学院/特种材料研究所,广州510006
  • 折叠

摘要

Abstract

BSA chiral columns were prepared based on column modification method with carbonyl imidazole as cross-linker. Enantioseparation of tryptophan, pidotimod and 4-phenyl-l,3-oxazolidine-2-thione (L-ben) was obtained on the BSA chiral column by HPLC. The effects of pH values and ionic strength of mobile phase on enantioseparation performance were investigated. For L-tryptophan, the retention factor (k') increased significantly as the pH value increased from 5. 0 to 7. 0. While for D-tryptophan k' rarely changed and the resolution factor (Rs) increased froml. 15 to 8. 91. In contrast, the retention factor (k ) for RS- and SR-pidotimod decreased as the pH value increased from 5. 0 to 7. 0. For L-ben, k' was only a slight increase when the pH value increased. The retention factors of three enantiomers fluctuated as ionic strength increased. However, Rs decreased when a buffer concentration increased.

关键词

牛血清蛋白(BSA)/高效液相色谱/手性分离/pH值/离子强度

Key words

Bovine serum albumin/High performance liquid chromatography/Chiral separation/pH value/Ionic strength

引用本文复制引用

熊雅进,苏文翠,章伟光,范军,郑盛润,林纯..流动相的pH值和离子强度对牛血清蛋白高效液相色谱手性柱分离性能的影响[J].分析化学,2012,40(1):89-94,6.