| 注册
首页|期刊导航|福州大学学报(自然科学版)|无喷淋室内火灾烟气温度变化特性的实验研究

无喷淋室内火灾烟气温度变化特性的实验研究

陈伯辉

福州大学学报(自然科学版)2011,Vol.39Issue(6):952-955,4.
福州大学学报(自然科学版)2011,Vol.39Issue(6):952-955,4.DOI:35-1117/N.20111220.0939.010

无喷淋室内火灾烟气温度变化特性的实验研究

Experimental research on temperature change characteristics of fire smoke no water spray indoor

陈伯辉1

作者信息

  • 1. 福州大学环境与资源学院,福建福州350108
  • 折叠

摘要

Abstract

Having experiments by test platform which was designed and builted by ourselves in these three conditions: airtight without spraying, natural draught, both of natural ventilation and mechanical exhaust. The results showed that; the distribution regularity of smoke distribution in the process of transmission of fire smoke indoor is that both of the speed of gas temperature rise and the gas temperature in the high level are a litte higher than the speed and temperature in the low level, so the strength of discharge is the major factor deciding the temperature of fire smoke.

关键词

无喷淋/室内火灾/烟气温度/排烟方式

Key words

no water spray/ fire indoor/ smoke temperature/ smoke venting way

分类

资源环境

引用本文复制引用

陈伯辉..无喷淋室内火灾烟气温度变化特性的实验研究[J].福州大学学报(自然科学版),2011,39(6):952-955,4.

基金项目

福建省教育厅科研资助项目(JB06053) (JB06053)