摘要
Abstract
To enhance the efficiency of inspection and repair, fault types of control circuit of high voltage circuit breaker are analyzed, and the characteristics of hidden faults in the control circuit are described. A case study of the hidden faults inspection demonstrates the effectiveness and rapidness of the inspection and repair method. In addition, the main causes of hidden faults are analyzed, and corresponding countermeasures are offered.关键词
控制回路/隐性故障/检修方法Key words
control circuit/hidden fault/inspection and repair method分类
信息技术与安全科学引用本文复制引用
崔勇,王川,杨锦红,朱宝,刘东海..高压断路器控制回路隐性故障检修方法[J].高压电器,2011,47(12):96-99,4.