| 注册
首页|期刊导航|环境工程学报|厌氧滤池处理纺织印染废水的中试研究

厌氧滤池处理纺织印染废水的中试研究

付志敏 张玉高 汪晓军

环境工程学报2012,Vol.6Issue(2):535-539,5.
环境工程学报2012,Vol.6Issue(2):535-539,5.

厌氧滤池处理纺织印染废水的中试研究

Pilot study on textile wastewater treatment by anaerobic filter reactor

付志敏 1张玉高 2汪晓军3

作者信息

  • 1. 广东溢达纺织有限公司,佛山528500/华南理工大学环境科学与工程学院,广州510640
  • 2. 广东溢达纺织有限公司,佛山528500
  • 3. 华南理工大学环境科学与工程学院,广州510640
  • 折叠

摘要

Abstract

A pilot scale of the anaerobic filter(AF) reactor was used to treat textile wastewater.The experimental result indicates that the average COD removal efficiency is 20% when the hydraulic retention time(HRT) of the AF is between 8.1~14.6 h and the influent COD concentration fluctuates between 500 mg/L and 1 000 mg/L.The BOD5/COD ratio of textile wastewater increases from 0.23 to 0.35 which demonstrates that biodegradability of the textile wastewater is improved significantly.The effluent sulfate concentration decreased during the operation period,and the removal concentration was about 70 mg/L during the operation period.The UV-Visible spectrums analysis suggests the degradation of influent organic materials.