资源调查与环境2011,Vol.32Issue(4):307-310,4.
电感耦合等离子体发射光谱法测定地下水中锰的不确定度评定
Evaluating on uncertainty of determination of manganese contents in groundwater by inductively coupled plasma atomic emission spectrometry
摘要
Abstract
The uncertainty of determination of manganese contents in groundwater by inductively coupled plasma atomic emission spectrometry(ICP-AES) was evaluated in this paper.The calculating model of double error fitting in the course of standard curve fitting was used,and the mathematical evaluation model for uncertainty was also established.In addition,the uncertainty of the determination of manganese contents in groundwater samples was evaluated.关键词
不确定度/双误差拟合/电感耦合等离子体发射光谱/锰/地下水Key words
uncertainty/double error fitting/ICP-AES/manganese contents/groundwater分类
天文与地球科学引用本文复制引用
蔡述伟,朱家平,王爱华,李华玲..电感耦合等离子体发射光谱法测定地下水中锰的不确定度评定[J].资源调查与环境,2011,32(4):307-310,4.基金项目
国家公益性行业科研专项资金项目(编号:200811133)资助 ()