净水技术2011,Vol.30Issue(6):28-30,52,4.
Fenton试剂氧化法对染料中间体废水的深度处理
Advanced Treatment of Dye Intermediate Wastewater by Fenton Reagent Oxidation Process
任国栋 1魏宏斌 1唐秀华 2张英 1陈良才1
作者信息
- 1. 同济大学环境科学与工程学院,上海 200092
- 2. 上海中耀环保实业有限公司,上海 200092
- 折叠
摘要
Abstract
On the basis of the actual dye intermediate wastewater treated by iron-catalyzed internal electrolysis, hydrolytic-acidifi-cation and aerobic biochemical process, the efficiency and influencing factors in advanced treatment by Fenton reagent oxidation process were investigated. When the influent CODυ is 187.5 mg/L and the color is 1 085 times, the effluent CODυ is decreased to 59.2 mg /L, its removal rates being 68.4 %, and color is decreased to 129 times, its removal rates being 88.1 %.关键词
染料中间体废水/Fenton试剂/氧化/深度处理/影响因素Key words
dye intermediate wastewater/Fenton reagent/oxidation/advanced treatment/influencing factors分类
建筑与水利引用本文复制引用
任国栋,魏宏斌,唐秀华,张英,陈良才..Fenton试剂氧化法对染料中间体废水的深度处理[J].净水技术,2011,30(6):28-30,52,4.