机械科学与技术2011,Vol.30Issue(9):1511-1514,4.
医用电梯的设计计算
Designing and Calculating Parameters of Medical Elevator
摘要
Abstract
In order to increase the running speed of a heavyweight medical elevator to 1.6m/s and smooth running,we should first design and calculate its configuration design,thus avoiding its slipping due to the lack of gravitation and car shake caused by insufficient strength.Taking a 1.6 m/s midsplit medical elevator as an example and following the new standards in safety rules for the construction and Installation of Electric Lifts(2003 Version),we design and calculate such key parameters of the medical elevator as traction force,safety coefficients of its suspension ropes and the load of its linear motion rolling guide,thus obtaining its reasonable transmission mechanisms and correct parameters and providing a solid theoretic basis for its production,installation and acceptance.关键词
曳引机/曳引力计算/悬挂装置/导轨验算Key words
medical elevator/traction force/load/suspension rope/suspension/parameter/rolling guide分类
机械制造引用本文复制引用
郭辉,张晓妍..医用电梯的设计计算[J].机械科学与技术,2011,30(9):1511-1514,4.