| 注册
首页|期刊导航|建筑结构学报|HRBF500级钢筋混凝土梁受火后力学性能试验研究

HRBF500级钢筋混凝土梁受火后力学性能试验研究

王全凤 邱毅 徐玉野 王凌云 陈凡

建筑结构学报2012,Vol.33Issue(2):50-55,6.
建筑结构学报2012,Vol.33Issue(2):50-55,6.

HRBF500级钢筋混凝土梁受火后力学性能试验研究

Experimental research on mechanical properties of HRBF500 concrete beam after fire

王全凤 1邱毅 2徐玉野 2王凌云 3陈凡3

作者信息

  • 1. 华侨大学厦门工学院,福建厦门361021
  • 2. 华侨大学土木工程学院,福建泉州362021
  • 3. 上海应用技术学院土木建筑与安全工程学院,上海201418
  • 折叠

摘要

Abstract

This paper conducts an experimental study on the mechanical properties of the fine grain reinforced concrete beam with HRBF500 at normal temperatures and after fire. The experiments of five fine grain reinforced concrete beams under fire with different time were accomplished. The static loading test was done when the beams were cooled to room temperature naturally. Its macroscopical phenomenon and the static failure modes were investigated through the tests. Hence, the variation of the bearing capacity of the fine grain reinforced concrete beams by the fire was obtained under different conditions. The tests of two fine grain reinforced concrete beams under loads without fire were carried out. The load-deflection curves were obtained and compared with the results after fire. The results show that the concrete beams can be seriously damaged by fire. The effects of the time of fire, bar ratio and preloading on the fire resistance are revealed. Some conclusions are drawn: The longer it is exposed to fire, the weaker its residual bearing capacity is. The smaller the bar ratio is, the weaker its residual bearing capacity is; A preloading will reduce the residual bearing capacity of the fine grain reinforced concrete beam.

关键词

细晶粒钢筋/受火时间/受火试验/剩余承载力

Key words

hot rolled bars of fine grains/time of fire/fire test/residual bearing capacity

分类

建筑与水利

引用本文复制引用

王全凤,邱毅,徐玉野,王凌云,陈凡..HRBF500级钢筋混凝土梁受火后力学性能试验研究[J].建筑结构学报,2012,33(2):50-55,6.

基金项目

国家高技术研究发展计划(863)项目(2007AA032550),福建省青年科技人才创新项目(2007F3064). ()