| 注册
首页|期刊导航|南方电网技术|配电网电容电流测试研究

配电网电容电流测试研究

冉启鹏 胡之荣 字美荣 杨春雨 王裕喜 袁峻 李维昆

南方电网技术2011,Vol.5Issue(4):81-85,5.
南方电网技术2011,Vol.5Issue(4):81-85,5.

配电网电容电流测试研究

Study on the Test of Distribution Network’s Capacitive Current

冉启鹏 1胡之荣 1字美荣 1杨春雨 1王裕喜 1袁峻 1李维昆1

作者信息

  • 1. 云南电网公司昆明供电局修试所,昆明650200
  • 折叠

摘要

Abstract

With the constant expansion of distribution network,it is necessary to test the capacitance current and check whether it is over the standard.Comparing several testing-in-field methods of distribution network’s capacitance current,this paper chooses the signal injection method to carry out most of the current tests in field of 27 substations in 10 kV/35 kV systems of Kunming Power Grid,and calculates the currents of the substations at which the measured values are relatively larger,pointing out that the difference between the measured and theoretical values is due to the factors of improper test method,change of system’s operation mode and so on.For several types of abnormal cases,the solutions are given in the paper.

关键词

配电网/变电站/电容电流/测试方法

Key words

distribution network/substation/capacitance current/test method

分类

信息技术与安全科学

引用本文复制引用

冉启鹏,胡之荣,字美荣,杨春雨,王裕喜,袁峻,李维昆..配电网电容电流测试研究[J].南方电网技术,2011,5(4):81-85,5.