| 注册
首页|期刊导航|宁夏电力|凝汽器胶球清洗系统收球率低原因分析

凝汽器胶球清洗系统收球率低原因分析

姜拥军

宁夏电力Issue(6):40-43,4.
宁夏电力Issue(6):40-43,4.

凝汽器胶球清洗系统收球率低原因分析

Cause analysis of the low recovery rate of rubber ball in cleaning system of the condenser

姜拥军1

作者信息

  • 1. 宁夏大唐国际大坝发电有限责任公司,宁夏青铜峡751607
  • 折叠

摘要

Abstract

Through analyzing the internal structure of the small turbine condenser,finds out low ball recovery rate of the rubber ball cleaning system in the small turbine is caused by the design irrationalness of the water room in the condenser and the rubber ball pump sealing,etc.,so puts forward the retrofit schemes and makes implementation.

关键词

胶球收球率/凝汽器结构/胶球清洗系统

Key words

ball recovery rate of the rubber ball/structure of the condenser/rubber ball cleaning system

分类

能源科技

引用本文复制引用

姜拥军..凝汽器胶球清洗系统收球率低原因分析[J].宁夏电力,2011,(6):40-43,4.