Abstract
Through analyzing the internal structure of the small turbine condenser,finds out low ball recovery rate of the rubber ball cleaning system in the small turbine is caused by the design irrationalness of the water room in the condenser and the rubber ball pump sealing,etc.,so puts forward the retrofit schemes and makes implementation.关键词