气象水文海洋仪器2011,Vol.28Issue(3):114-116,121,4.
CAWS600-S型自动气象站雷击故障的分析与排除
Analysis and elimination of lightning fault of CAWS600-S automatic weather station
邬铭法 1蔚立存 1董秀荣1
作者信息
- 1. 山东省雷电防护技术中心,济南250031
- 折叠
摘要
Abstract
Through maintenance for lightning faults of automatic weather station in Huimin, this paper introduces troubleshooting processes, maintenance steps and emergency measures to reduce data missing for lightning faults of CAWS600-S automatic weather station. Aiming at the abnormalities happened in the troubleshooting processes and component replacement procedure, effective approaches are proposed that can be referenced for other personnel engage in maintenance of automatic weather station.关键词
自动站/雷击/检修Key words
automatic weather station/lighting/maintenance分类
机械制造引用本文复制引用