Abstract
The study on transient process and the hydraulic model test of headrace-generation system of hydropower stations with large discharge and low-to-medium head is a new topic in recent years. For determining the layout of headrace system and the type of surge chamber of Luding Hydropower Station, the hydraulic model tests are conducted for the headrace-generation system. Based on the similarity law of unsteady flow in pressure diversion systems, the similarity conditions for the hydraulic model and the prototype are derived. The surge chamber designs are compared by the tests, and the tests also demonstrate that the layout of headrace-generation system is reasonable. These tests provide a basis for engineering design.关键词
中低水头水电站/引水发电系统/水工模型试验/泸定水电站Key words
hydropower station with low-to-medium head/ headrace-generation system/ hydraulic model test/ Luding Hydropower Station分类
建筑与水利引用本文复制引用