| 注册
首页|期刊导航|实用医学杂志|应用99mTc-DTPA肾动态显像和双血浆法评估肾小球滤过率的一致性研究

应用99mTc-DTPA肾动态显像和双血浆法评估肾小球滤过率的一致性研究

姚红霞 张金山 王淑侠 徐卫平

实用医学杂志2012,Vol.28Issue(3):395-398,4.
实用医学杂志2012,Vol.28Issue(3):395-398,4.DOI:10.3969/j.issn.1006-5725.2012.03.020

应用99mTc-DTPA肾动态显像和双血浆法评估肾小球滤过率的一致性研究

doi:10.3969/j.issn.1006-5725.2012.03.020Comparison and analysis of GFR measurements assessed from gates method of dynamic renal imaging ana 99mTc-DTPA clerarance of double samples

姚红霞 1张金山 1王淑侠 2徐卫平2

作者信息

  • 1. 510160,广州医学院第三附属医院核医学科
  • 2. 510000,广州市,广东省医学科学院,广东省人民医院核医学科
  • 折叠

摘要

Abstract

Objective The aim of this study was to assess clinical accuracy of GFR measurements assessed from gates methods of dynamic renal imaging by considering the 99mTc-DTPA-dual blood sample method as the reference in patients with different kidney diseases. Methods The study was performed in 202 patients between June 2009 and June 2010 with various degrees of renal function varied from normal to severely impaired [123 males and 79 females, age (49.5 ± 3.9) years old]. There were 398 kidneys. The GFR of each kidney was measured by gates and two-sample method. According to 99mTc-DTPA-dual blood sample method (dGFR). These patients were divided into 5 groups as follows: normal(≥40), 4(30~39.9), 3(20~29.9), 2(10~19.9), 1 ( < 10) [mL·min-1· (1.73 m2)-1]. Pearson correlation analysis was used between GFR from gates and dGFR in all groups. Bland-Altman plotting was also performed to define the 95% limits of agreement, which was presented as bias ± 1.96 s. Results There were 28 patients and 23 kidneys, 16 patients and 42 kidneys, 22 patients and 40 kidneys, 21 patients and 45 kidneys, 20 patients and 34 kidneys in normal, 4, 3, 2, 1 group respectively. (1) Pearson correlation analysis showed good correlation between gates and double-sample method (r = 0.722, P= 0.000) in total patients, the linear regression equation was gates = 16.708 + 0.505 dGFR. The same correlations were poor in 3, 4 and normal group (r = 0.341, P = 0.002, r = 0.368, P = 0.002 and r = 0.319, P = 0.004, respectively). The linear regression equation was respectively gates = -9.7 + 1.899 dGFR, gates = 31.671 + 0.060 dGFR and gates = 17.225 + 0.879 dGFR. There were no statically difference between group 1 and 2 (r = 0.038, P = 0.747 and r = 0.198, P= 0.077). (2)The concordance study using the Bland-Altman method showed that there was poor consistency between gates and dGFR in all groups. Conclusions Dynamic renal imaging was acceptable for estimating GFR, but better correct GFR was assessed by linear regression equation according to dGFR. However, double-sample method should be recommended for accurate determination of the GFR in group 1 and 2.

关键词

肾小球滤过率/肾动态显像/双血浆法/99mTc-DTPA

Key words

Glomerular filtration rate/ Dynamic renal imaging/ Double-sample method/ 99mTc-DTPA

引用本文复制引用

姚红霞,张金山,王淑侠,徐卫平..应用99mTc-DTPA肾动态显像和双血浆法评估肾小球滤过率的一致性研究[J].实用医学杂志,2012,28(3):395-398,4.

实用医学杂志

OA北大核心CSTPCD

1006-5725

访问量0
|
下载量0
段落导航相关论文