烟草科技Issue(12):34-37,42,5.
微波消解-石墨炉原子吸收光谱法测定水基胶中的铅和砷
Determination of Lead and Arsenic in Water-based Adhesives by Microwave DigestionGraphite Furnace Atomic Absorption Spectrometry
廖惠云 1张映 1熊晓敏 1庄亚东1
作者信息
- 1. 江苏中烟工业有限责任公司技术研发中心,210019
- 折叠
摘要
Abstract
A method for analyzing lead (Pb) and arsenic (As) in water-based adhesives for cigarette was developed by microwave digestion-graphite furnace atomic absorption spectrometry. The results of tested samples showed that: under the optimized conditions, in the linear ranges of 0-50 ug/L (Pb) and 0-20 ug/L (As), the linear coefficients, limits of detection, relative standard deviations (RSDs), and recoveries were 0.9992 and 0.9995, 0.075 and 0.037 mg/kg, 6.77% and 9.86% , 87.97%-92.35% and 93.37%-108.92% , respectively. The contents of Pb and As were less than 5 and 1 mg/kg, respectively. The method was suitable for the quantitative analysis of lead and arsenic in water-based adhesives for cigarette.关键词
微波消解/石墨炉原子吸收光谱/烟用水基胶/铅/砷Key words
Microwave digestion/Graphite furnace AAS/ Water-based adhesive for cigarette/Lead/Arsenic分类
轻工纺织引用本文复制引用
廖惠云,张映,熊晓敏,庄亚东..微波消解-石墨炉原子吸收光谱法测定水基胶中的铅和砷[J].烟草科技,2011,(12):34-37,42,5.