原子能科学技术2011,Vol.45Issue(10):1198-1202,5.
CPR1000非能动应急给水系统瞬态特性分析
Transient Analysis of Passive Emergency Feedwater System of CPR1O00
张亚培 1田文喜 2秋穗正 1苏光辉2
作者信息
- 1. 西安交通大学动力工程多相流国家重点实验室,陕西 西安 710049
- 2. 西安交通大学核科学与技术学院,陕西 西安 710049
- 折叠
摘要
Abstract
The transient thermal hydraulic characteristics of CPR1000 were analyzed by using RELAP5/MOD3. 4 code to verify the capability of the passive emergency feedwa-ter system (PEFWS) for accident mitigation under the condition of station blackout accident (SBO). The calculation results show that the PEFWS of CPR1000 can supply the water to steam generator immediately and remove the core residual heat after the SBO successfully, and it also shows that the design of the PEFWS of CPR1000 is successful.关键词
RELAP5/MOD3.4程序/CPR1000/全厂断电事故/PEFWSKey words
RELAP5/MOD3. 4 code/ CPR1000/ station blackout accident/ PEFWS分类
能源科技引用本文复制引用
张亚培,田文喜,秋穗正,苏光辉..CPR1000非能动应急给水系统瞬态特性分析[J].原子能科学技术,2011,45(10):1198-1202,5.