摘要
Abstract
The specific activity of 60Co radioactive solution and Mco+99Tc mixing solution was absolutely measured by coincidence method. The specific activity of "Tc solution was calculated by efficiency tracing method with 60Co as tracer isotope. Final result is that the specific activity of 99Tc solution is (70. 8±1. 8) Bq · mg-1 (k = 2), which can meet the need of measurement task.关键词
活度测量/4πβ-γ符合法/效率示踪法Key words
activity measurement/ 4π-γ coincidence method/ efficiency tracing method分类
能源科技引用本文复制引用