中国电机工程学报2011,Vol.31Issue(26):23-31,9.
高效褐煤发电系统研究
Study on Efficient Lignite-fired Power System
郭晓克 1肖峰 1严俊杰 2谭红军 1郭兆君 1刘明2
作者信息
- 1. 东北电力设计院,吉林省长春市130021
- 2. 西安交通大学能源与动力工程学院,陕西省西安市710049
- 折叠
摘要
Abstract
Lignite is a kind of low rank coal with high water and ash content, which has low power generation efficiency. In order to improve the efficiency of lignite-fried power system, efficient lignite-fired power system was introduced. Theoretical analysis and calculation were carried out on this system with equivalent heat drop method. Moreover, technical and economic comparison of a 600 MW supercritical power plant was carded out. Through theoretical calculation, this system can reduce power generating consumption rate 12 g/(kW.h) in the benchmark condition stated. Through technical economy analysis, the system can reduce the power system service consumption rate by 0.56% and power supplying consumption rate 15 g/(kW.h). And at the same time, this system can also reduce pollutants and engineering investment et al. This study finds that burning high moisture content lignite with efficient lignite-fired power system is of great advantage.. This system is energy and water saving and pollutions reduction, which is popularized "green" lignite-fire power system.关键词
火力发电厂/抽汽干燥/理论分析/工程案例/节能减排Key words
thermal power plant/extraction steam drying/theoretical analysis/project case/energy conservation分类
信息技术与安全科学引用本文复制引用
郭晓克,肖峰,严俊杰,谭红军,郭兆君,刘明..高效褐煤发电系统研究[J].中国电机工程学报,2011,31(26):23-31,9.