Objective:To evaluate SPECT planar imaging performances and conduct the acceptance test to provide basis for patient safety and image quality in clinical practice. Methods:SPECT planar imaging performances intrinsic spatial resolution, intrinsic spatial linearity, intrinsic energy resolution, intrinsic uniformity, maximum count rate and system planar sensitivity were tested for two types of SPECT devices. Results:There was a little difference between the performances of two types of SPECT devices. The intrinsic spatial resolution and intrinsic spatial linearity for type 1 were better than type 2, and the system planar sensitivity and intrinsic energy resolution for type 2 were better than type 1. Conclusion:Performances of two types of SPECT devices come to the manufacture’s standard and meet the demands for clinical practice.