制冷学报2011,Vol.32Issue(2):23-26,4.DOI:10.3969/j.issn.0253-4339.2011.02.023
基于六流程微通道冷凝器的空调样机实验研究
Experimental Research on Air Conditioner Prototype with 6-pass Microchannel Condenser
鲁红亮 1陶红歌 2胡云鹏 3胡浩茫 3金听祥 3陈焕新3
作者信息
- 1. 上海硅酸盐研究所 上海 200050
- 2. 上海汽车集团股份有限公司 上海 201804
- 3. 华中科技大学 武汉 430074
- 折叠
摘要
Abstract
A 6kW window type air conditioner prototype with 6-pass microchannel condenser was developed and investigated experimentally under T, standard, T3 standard and T3 maximum operating conditions. The result showed that under T, standard operating condition the new developed prototype performed better than the one with traditional finned copper round tube heat exchanger: 254W(about 4.27%) higher in refrigerating capacity, 204W less in input power and 12.32% higher in EER(I.e., 2.28), which revealed better performance. Under T3 standard and T3 maximum operating condition it operated normally, which verified the reasonable configuration and superior performance of the prototype.关键词
热工学/样机实验/微通道冷凝器/窗式空调Key words
Pyrology/Experiment/MicroChannel condenser/Window type air conditioner分类
通用工业技术引用本文复制引用
鲁红亮,陶红歌,胡云鹏,胡浩茫,金听祥,陈焕新..基于六流程微通道冷凝器的空调样机实验研究[J].制冷学报,2011,32(2):23-26,4.